Optimal Operating Point Calculation for Medium Voltage Distribution Systems
2007
The paper deals with the calculation of the optimal working point of a distribution system, equipped with several distributed generators, able to operate also autonomously, i.e. disconnected from the main grid. When connected to the main grid, it appears in general convenient to assign the slack bus role to the bus that represents such a connection. The problem becomes more complex when maximum power transfer constraints through the connection must be taken into account. The adequate slack bus treatment is even more important when the optimal operating condition must refer to the condition subsequent to an intentional or unintentional disconnection from the main grid. The paper presents an …
Eco-sustainable energy and environmental strategies in design for recycling: the software “ENDLESS”
2003
Abstract This paper describes a model, named “ENDLESS”, useful to address the design process towards more eco-compatible solutions. In particular, this tool can support the designer in the choice of the product with an higher recyclability potential from a set of different alternatives. The model takes into consideration a Multi-Attribute Decision-Making method and allows calculating a “Global Recycling Index” (GRI) starting from a set of energy, environmental, technical and economic indicators. A weight is assigned to each parameter following the experience of the designer; a sensitivity analysis is then performed to state how the different assumptions can affect the final results. The mod…
Secondary substation power line communications for medium voltage smart grids
2012
In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…
Experimental investigation on PLC signal crossing of power transformers
2014
In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
Distraplan: a flexible tool for strategical planning of electrical distribution systems considering distributed generation.
2005
The paper here presented describes and shows DISTRAPLAN (Distribution Strategical Planning), software tool for strategical planning of distribu tion networks at Medium and Low voltage. The software aims at the identification and comparison of network configur ations, optimized in the long term with identification of special features in relation to the main technical-economical-environmental aspects, such as: the number of HV/MV and MV/LV substations, total length of the MV and LV lines and relevant sections, maximum required energy and power, instal lation and losses costs, etc. DISTRAPLAN, in both the main procedures into which it is articulated (strategical planning and evaluation of the …
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
ATLAS technical coordination expert system
2019
When planning an intervention on a complex experiment like ATLAS, the detailed knowledge of the system under intervention and of the interconnection with all the other systems is mandatory. In order to improve the understanding of the parties involved in an intervention, a rule-based expert system has been developed. On the one hand this helps to recognise dependencies that are not always evident and on the other hand it facilitates communication between experts with different backgrounds by translating between vocabularies of specific domains. To simulate an event this tool combines information from different areas such as detector control (DCS) and safety (DSS) systems, gas, cooling, vent…
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…